12 17.5 24kV Indoor Vacuum Circuit Breakers, GPVN-E Series
Imeko ye-Ambient
Ubushushu be-Ambient: -25℃~+45℃, umndilili wemihla ngemihla: ≤35℃
Ukuphakama: 1000m(Standard);ingaya kuthi ga kwi-4500m ukulungiselela iodolo ekhethekileyo;
Ukufuma okuhambelanayo: umyinge wemihla ngemihla ≤95%, umyinge wenyanga ≤90%;
Ubunzulu benyikima ≤8 degree;
Izihlandlo ezisebenzayo kufuneka zingabikho kwizinto ezinokutsha, kwiziqhushumbisi, kwizidlelezi kunye nokungcangcazela okukhulu.
Umzekelo
GPVN -12Kv/17.5kV Ngaphakathi AC High Voltage Vacuum Circuit Breaker
IiNgcaciso zobuGcisa
Hayi. | Into | Iyunithi | Idatha | ||||||
1 | Umbane olinganisiweyo | kV | 7.2~12(15/17.5) | ||||||
2 | Ilinganiswe rhoqo | Hz | 50/60 | ||||||
3 | Ikalwe ngoku | A | 630,1000,1250 | 1600 | 2000,2500,3150 | 4000 | |||
4 | Ireyithwe kwi-short-circuit breaking current | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
5 | Ilinganiswe kwi-short-circuit yangoku | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
6 | Ilinganiswe ngexesha elifutshane lokumelana nangoku | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
7 | Incopho elinganisiweyo ukumelana yangoku | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
8 | Ilinganiswe ngokutsalwa ngaphandle kwangoku | kA | 12.6 | 12.6 | 16 | 16 | 20 | ||
9 | Ilinganiswe ngenxa yempazamo yokwaphuka komhlaba ngaphandle kwesigaba | kA | 17.4 | 21.7 | 27.4 | 27.4 | 34.7 | 34.7 | 43.5 |
10 | Ilinganiswe ngexesha loqhawulo lwesekethe emfutshane yangoku | Amaxesha | 50 | 30 | 30 | 12 | |||
11 | Ulandelelwano lomsebenzi olukalisiweyo | O-0.3s-CO-180s-CO | O-180s-CO-180s-CO | ||||||
12 | Ilinganiswe ngokwaphulwa kwangoku kwibhanki enye ye-capacitor | A | 630 | ||||||
13 | Ilinganiswe ngokwaphulwa kwangoku kwibhanki ye-capacitor yangasemva | A | 400 | ||||||
14 | 1min.Amandla ombane axhathise amandla ombane | kV | Inqanaba ukuya kwisigaba/ emhlabeni: 42, ngapha koqhagamshelwano oluvulekileyo:48 | ||||||
15 | Impembelelo yombane imelana nombane | kV | Inqanaba ukuya kwisigaba/ emhlabeni: 75, ngapha koqhagamshelwano oluvulekileyo:85 | ||||||
16 | Ubomi bomatshini | Amaxesha | 20000 | ||||||
17 | Ixesha lokuvala | ms | ≤75 | ||||||
18 | Ixesha lokuvula | ms | ≤60 | ||||||
19 | Ixesha lokugcinwa kwamandla phantsi kombane olinganisiweyo | s | ≤10 |
Ubungakanani boMda we-GPVN-12E
GPVN-24 □ Ngaphakathi AC High Voltage Vacuum Circuit Breaker
Inkcazo yobuGcisa
Hayi. | Into | Iyunithi | Idatha | |||
1 | Umbane olinganisiweyo | kV | 24 | |||
2 | Ilinganiswe rhoqo | Hz | 50/60 | |||
3 | Ikalwe ngoku | A | 630 1250 1600 2000 2500 3150 4000 | |||
4 | Ireyithwe kwi-short-circuit breaking current | kA | 20 | 25 | 31.5 | 31.5 |
5 | Ilinganiswe kwi-short-circuit yangoku | kA | 50 | 63 | 80 | 80 |
6 | Ilinganiswe kwi-short-circuit ukumelana nangoku (4s) | kA | 20 | 25 | 31.5 | 31.5 |
7 | Incopho elinganisiweyo ukumelana yangoku | kA | 50 | 63 | 80 | 80 |
8 | Ilinganiswe ngaphandle-kwenyathelo ngokuqhekeza okwangoku | kA |
|
| 12.6 | 12.6 |
9 | Ilinganiswe ngokuqhawuka kwangoku kwempazamo yomhlaba engaphandle kwesigaba | kA | 17.4 | 21.7 | 27.4 | 27.4 |
10 | Ireyithwe ngamaxesha okuqhawuka kwe-short-circuit yangoku | Amaxesha | 50 | |||
11 | Ulandelelwano lokusebenza olukalwe |
| O-0.3s-CO-180s-CO | |||
12 | Ilinganiswe ngokwaphulwa kwangoku kwibhanki enye ye-capacitor | A | 630 | |||
13 | Ilinganiswe ngokwaphulwa kwangoku kwebhanki ye-capacitor ebuyela umva | A | 400 | |||
14 | 1min.Amandla ombane axhathise amandla ombane | kV | 50 | |||
15 | Impembelelo yombane imelana nombane | kV | 125 | |||
16 | Ubomi bomatshini | Amaxesha | 20000 | |||
17 | Ixesha lokuvala | ms | 75 | |||
18 | Ixesha lokuvula | ms | 60 | |||
19 | Ixesha lokugcinwa phantsi kombane olinganisiweyo | s | 10 |