40.5kV SF6 Circuit Breaker GPFN Series
Umzekelo kunye nentsingiselo
Sebenzisa iMiqathango yokuSingqongileyo
a.Ukuphakama: akukho ngaphezu kwe-1000m
b.Ubushushu be-Ambient: -15℃~+40℃, i-avareji yobushushu bemihla ngemihla ayidluli +35℃
c.Ukufuma kokusingqongileyo: umndilili wemihla ngemihla wokufuma okuzalanayo: ≤95% umyinge wenyanga wokufuma ozalanayo: ≤90%
Uxinzelelo lwemihla ngemihla lomphunga: ≤2.2x10-3 MPa Umyinge woxinzelelo lomphunga wenyanga: ≤1.8x10-3MPa
d.Ubunzulu benyikima: akukho ngaphezu kwe-8 degrees
e.Indawo osetyenziswa kuyo: Umoya okwi-Ambient awungcoliswa ngokuncomekayo luthuli, umsi, izinto ezidliwayo kunye/okanye iigesi ezinokutsha, umphunga okanye inkungu yetyuwa.
Qaphela: Xa eyona ndawo yokusetyenziswa ingahambelani nale miqathango ingasentla, nceda uqhagamshelane nenkampani yethu.
IParameter yobuGcisa
Hayi. | Izinto | Iyunithi | Idatha | |||
1 | Umbane olinganisiweyo | kV | 40.5 | |||
2 | Ilinganiswe rhoqo | Hz | 50 | |||
3 | I-1min yamaxesha ombane wokuxhathisa amandla ombane | Phakathi kweepali, Ukuya emhlabeni | kV | 95 | ||
Ukwaphuka | 118 | |||||
Impembelelo yombane ukumelana nombane | Phakathi kweepali, Ukuya emhlabeni | 185 | ||||
Ukwaphuka | 215 | |||||
4 | Ikalwe ngoku | A | 1250 1600 2000 2500 | |||
5 | Ilinganiswe ngexesha elifutshane lokumelana nangoku (RMS) | kA | 25 | 31.5 | ||
6 | Incopho elinganisiweyo ukumelana yangoku | 63 | 80 | |||
7 | Ilinganiswe kwi-short-circuit breaking current (RMS) | 25 | 31.5 | |||
8 | Ulinganiso lwendlela emfutshane yokwenza yangoku (ixabiso eliphezulu) | 63 | 80 | |||
9 | Ilinganiswe ngexesha elifutshane lesekethe | s | 4 | |||
10 | Ulandelelwano olulinganisiweyo lwemisebenzi | O-0.3s-CO-180s-CO | ||||
11 | Ilinganiswe ngaphandle kwesigaba somhlaba ngenxa yempazamo yokwaphulwa kwamandla | kA | 21.7 | 27.4 | ||
12 | Uvavanyo lokutshaja kwentambo yangoku | A | 50 | |||
13 | Ireyithwe enye/i-back-back-back capacitor bank breaking current | 800/800 | ||||
14 | Ubomi bomatshini | amaxesha | 10000 | |||
15 | Isiphaluka esifutshane sangoku siqhekeza amaxesha | amaxesha | 30 | |||
16 | Isekethe yeSekondari 1 min frequency yamandla ombane ukumelana nombane | 2000 | ||||
17 | Ixabiso lombane osebenzayo | Ukuvala ikhoyili | V | DC110/220, AC220 | ||
Ikhoyili yokuvula | V | DC110/220, AC220 | ||||
18 | Umbane olinganisiweyo wemoto yokugcina amandla | W | DC110/220, AC220 | |||
19 | Amandla alinganisiweyo enjini yokugcina amandla | s | 250 | |||
20 | Ixesha lokugcina amandla (i-voltage elinganisiweyo) | s | ≤10 | |||
21 | Uxinzelelo olulinganisiweyo lwegesi ye-SF6 (uxinzelelo lwegeyiji kwi-20 ° C) | Mpa | 0.350+0.02 | |||
22 | Uxinzelelo lwe-alam | Mpa | 0.29±0.01 | |||
23 | Ubuncinci boxinzelelo olusebenzayo (uxinzelelo lokuthintela) | Mpa | 0.28±0.01 | |||
24 | Izinga lokuvuza lonyaka | % | ≤0.5 | |||
25 | Isiqulatho sokufuma kwerhasi | μL/L | ≤150 | |||
26 | Ukuhamba koqhagamshelwano | mm | ≥78 | |||
27 | iSithuba soQhakamshelwano | mm | 50±1.5 | |||
28 | Ixesha lokuvula | ms | 60~78 | |||
29 | Ixesha lokuvala | ms | 65~95 | |||
30 | Ukuvala kunye nokuvulwa kwezigaba ezithathu azikho ngamaxesha athile | ≤5 | ||||
31 | Isantya esiphakathi sokuvula (ngaphakathi kwe-10ms emva kwesiqingatha sendlela) | ms | 2.2~2.8 | |||
32 | Isantya esiphakathi sokuvala (ngaphakathi kwe-10ms emva kwesiqingatha sendlela) | ms | ≥1.5 | |||
33 | Uchaso oluphambili lwe-loop conductive | μΩ | ≤32(Inqwelo ephathwayo) | ≤20(uhlobo olulungisiweyo) |