I-ACB kunye ne-MCCB
Isishwankathelo
I-GPU1/2/3 Series smart universal air circuit breaker iyilwe imveliso ephuhliswe sithi, i-voltage elinganisiweyo ye-AC 50/60Hz, 480V(690V), i-200A ~ 6300A yangoku, isetyenziselwa ukuhanjiswa kwamandla kunye neesekethe zokukhusela ukuhanjiswa kwamandla. womnatha, uthintele unikezelo lwamandla kunye nomonakalo wezixhobo zombane kwimpazamo yomthwalo ogqithisileyo, i-short-circuit, impazamo yomhlaba, njl.I-breaker nayo inomsebenzi wokuzihlukanisa, ihambelana nomgangatho we-GB 14048.2, IEC 60947-2
Iimbonakalo
1. Ubume obubambeneyo
2. Akukho mgama weflashover Ukhuseleko oluphezulu
3. Umthamo ophezulu we-Off
4. Uhlobo lwe-Smart olungaphaya kokukhuselwa kohambo lwangoku, kunye nojongano lonxibelelwano, Inokulawulwa yiqela lekhompyuter, iqonde imisebenzi ekude.
5. Umsebenzi wokubonisa i-ammeter, i-voltmeter
6. Ukunyuka nokuhla okungenayo akuyi kuchaphazela ukusebenza kwemveliso
Umzekelo
GPU3 | I-Universal air circuit breaker |
1600 | Isakhelo seShield sangoku |
4 | 3 3-inqanaba aliphawuli 4 4-Isigaba |
Uhlobo lwe-3M lwesilawuli esilumkileyo | Umlawuli ohlakaniphile Uhlobo lwe-2M: Isiboniso setyhubhu yedijithali, ukulungiswa kweqhosha, icandelo le-3 kunye nomsebenzi wokukhusela impazamo yomhlaba Uhlobo lwe-3M: Umboniso we-LCD, ukulungiswa kweqhosha, icandelo le-3 elinomsebenzi wokukhusela impazamo yomhlaba Uhlobo lwe-3H: Umboniso we-LCD, ukulungiswa kweqhosha kunye nokunxibelelana, icandelo le-3 nge umsebenzi wokukhusela iziphene zomhlaba. |
Indlela yokunyuka | Uhlobo lokuzoba Uhlobo olusisigxina |
Connect indlela | Iingcingo ezithe tyaba zocingo oluthe tye Plate-ngasemva ucingo lwangaphambili |
Ukukhethwa kwezixhobo | Ngaphantsi kwe-voltage tripper I-Mechanical interlock: iiseti ezi-2 okanye iiseti ezi-3 ze-breaker kwi-lever ethe nkqo edibeneyo I-2 ibeka i-breaker ethe tye okanye ethe nkqo edityaniswe ngentambo yentsimbi Indawo yokutshixa “Vula” (isitshixo) I-draw-out 3 indawo yokutshintsha Umdibanisi wangaphandle wesigaba se-N |
Kwi=630 | Ikalwe ngoku(A) |
Phawula:
1. Umlawuli ohlakaniphile luhlobo lwe-M;Iswitshi encedisayo: Abafowunelwa bamaqela ama-4, Indlela yoqhagamshelo ithe tye.
2. Isilawuli esihlakaniphile, isixhobo sokukhulula i-shunt, i-electromagnetic evaliweyo, indlela yokuqhuba i-motor kunye ne-under-voltage tripper iya kuchazwa ixabiso lombane xa uodola.
Itheyibhile yokuKhetha yobuGcisa
Uhlobo | Ulinganiso lwamandla ombane osebenzayo i-Ue(V) | Ilinganiswe nge-insulating amandla ombane e-Ui(V) | Impembelelo elinganisiweyo yokumelana kwamandla ombane i-Uimp (V) | Isakhelo sekhaka i-Inm yangoku (A) | Ikalwe ngoku IM (A) | Inombolo yesigaba |
GPU1-1250 | AC400 AC690 | AC690, AC1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3, 4 |
GPU1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
GPU1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
GPU1-6300 | 6300 | 4000, 5000, 6300 |
Umthamo wokuqhekeka wesekethe emfutshane | Ilinganiswe ngexesha elifutshane ukumelana ne-Icw yangoku (kA)/1s | Ukusebenza komsebenzi | |||||
Ubungakanani bomthamo wokwaphuka kwesekethi emfutshane i-Icu (kA) | Ilinganiswe ukubaleka isakhono sokwaphulwa kwesekethi esifutshane Ics (kA) | Ubomi bomatshini (amaxesha) | Ubomi bombane (amaxesha) | ||||
400V | 690V | 400V | 690V | 400V | 690V | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000(5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
GPM11 Molded Case Circuit Breaker
GPM11Z Smart Molded Case Circuit Breaker
Isishwankathelo se-GPM11/GPM11Z
I-GPM11 uthotho olubunjiweyo lwesaphuli sesekethe ilungele i-AC 50/60Hz amandla ombane alinganisiweyo okusebenza 400V/630V, alinganiswe ngoku ukuya kuthi ga kwi-800A yothungelwano losasazo lwamandla okusasazwa kombane kunye neesekethe zokhuselo, unikezelo lwamandla kunye nezixhobo zombane ngokuchasene nokugcwala, ngaphantsi kwe-voltage kunye iingozi zesekethe ezimfutshane, iphucula ukuthembeka konikezelo lwamandla phantsi kweemeko zokusetyenziswa eziqhelekileyo ezingaqalisi rhoqo njengokuguqulwa komgca ongaqhelekanga kunye nemoto.Kwaye nomsebenzi wokuzihlukanisa ngokunjalo.Idibana nomgangatho we-GB / T 14048.2 kunye ne-IEC 60947-2.
Umzekelo
I-GPM11GPM11Z | Case Molded Circuit BreakerSmart Molded Case Circuit Breaker |
100 | Isakhelo seShield sangoku |
H | Umthamo wokuqhawuka kwesekethe emfutshane:N: Uhlobo oluqhelekileyo S: Uhlobo olusemgangathweniH: Uhlobo oluphezulu lokwaphuka |
P | Indlela yokusebenza: Ukusebenza kweemoto: Ukusebenza komqheba weProtate: Ukusebenza kweZDirect (akukho khowudi) |
2 | Indawo yokhuseleko Ukhetho: ukhuseleko losasazo: akukho khowudi Ukhuseleko lweMotor: 2 |
4 | Inombolo yenqanaba2: izigaba ezibini3: izigaba ezithathu4 : izigaba ezine |
208 | Indlela yohambo kunye nekhowudi yezixhobo zangaphakathi |
Kwi=100 | Ikalwe ngoku(A) |
B | Isigaba se-4 seSigaba se-N sineentlobo ezi-4 eziphawulwe njenge-A, B, C, DA: Isigaba se-N asiyi kufaka i-tripper yangoku, kwaye i-N ixhunyiwe rhoqo, ingasetyenziswanga kunye nezinye izigaba ze-3. B: Isigaba se-N asifaki i-tripper yangoku, kunye ne-N isigaba asisetyenziswanga kunye nezinye izigaba ezi-3.C: Isigaba se-N sifakwe i-tripper yangoku, kunye nesigaba se-N sisebenza kunye nezinye izigaba ezi-3.D: Isigaba se-N sifakwe i-tripper yangoku, kunye nesigaba se-N sixhunywe rhoqo, Ayisetyenziswanga kunye nezinye izigaba ze-3. |
Q | Indlela yocingo:Ngaphambi kocingo lwepleyiti: QNgasemva kocingo lwepleyiti: HI-Plug-in uhlobo lweingcingo: R |
Qaphela: 1. Indlela yocingo: ngasemva kwe-wiring yeplate (400, 630's 4P ngaphandle kwayo);i-plug-in uhlobo locingo (4P ngaphandle kwayo)
2. Izixhobo zangaphakathi zifakwe kwicala lasekhohlo le-breaker.
Itheyibhile yokukhetha yobugcisa ye-GPM11Z MCCB
Uhlobo | Ulinganiso lwamandla ombane osebenzayo i-Ue(V) | Ilinganiswe nge-insulating amandla ombane e-Ui(V) | Impembelelo elinganisiweyo ukumelana nombane we-Uimp (V) | Isakhelo sekhaka i-Inm yangoku (A) | Ikalwe ngoku IM (A) | Inombolo yesigaba | Umthamo wokuqhekeka wesekethe emfutshane | Ilinganiswe ngexesha elifutshane ukumelana ne-Icw yangoku (kA) 1s | Ukusebenza komsebenzi | ||
Ubungakanani bomthamo wokwaphuka kwesekethi emfutshane i-Icu (kA) | Ilinganiswe ukubaleka isakhono sokwaphulwa kwesekethi esifutshane Ics (kA) | Ubomi bomatshini (amaxesha) | Ubomi boMbane (amaxesha) | ||||||||
GPM11Z-100 | AC400 | AC690 | AC8000 | 100 | 32, 100 | 3,4 | 65 | 50 | 1 | 20000 | 8000 |
GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | 20000 | 8000 | ||||
GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Itheyibhile yokukhetha yobugcisa ye-GPM11 MCCB
Uhlobo | Ixabiso lombane osebenzayo i-Ue | Ixabiso lombane wokugquma i-Ui | Impembelelo elinganisiweyo imelana nombane we-Uimp | Udidi lwesakhelo lunikwe umlinganiselo wangoku kwi-Inm A | Ilinganiswe ngoku kwi (A) | Inombolo yesigaba | Ilinganiswe ngobuninzi bekhowudi yesakhono sokwaphulwa kwesekethe emfutshane | Ilinganiswe ngobuninzi mfutshane -umthamo wokuqhawuka kwesekethe | Ilinganiswe ukubaleka isakhono sokwaphulwa kwesekethi esifutshane Ics (kA) | Uhlobo lwesixhobo sohambo | Ukusebenza komsebenzi (amaxesha) | |
Phila | Hayi-Live | |||||||||||
GPM11- 63 | 400, 690 | 800, 1000 | 8 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 3 | N | 10 | 5 | Ubushushu be-electromagnetic | 3000 | 7000 |
3,4 | S | 25 | 18 | Ubushushu be-electromagnetic | ||||||||
3,4 | H | 50 | 35 | Ubushushu be-electromagnetic | ||||||||
GPM11-100 | 100 | 16, 20, 25, 32, 40, 50, 63, 80, 100 | 3 | N | 35 | 25 | Ubushushu be-electromagnetic | 3000 | 7000 | |||
3,4 | S | 50 | 35 | Ubushushu be-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ubushushu be-electromagnetic | ||||||||
GPM11-160 | 160 | 100, 125, 140, 160 | 3 | N | 35 | 25 | Ubushushu be-electromagnetic | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Ubushushu be-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ubushushu be-electromagnetic | ||||||||
GPM11- 225 | 225 | 100, 125, 140, 160, 180, 200, 225 | 3 | N | 35 | 25 | Ubushushu be-electromagnetic | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Ubushushu be-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ubushushu be-electromagnetic | ||||||||
GPM11- 250 | 250 | 100, 125, 140, 160, 180, 200, 225, 250 | 3 | N | 35 | 25 | Ubushushu be-electromagnetic | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Ubushushu be-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ubushushu be-electromagnetic | ||||||||
GPM11-400 | 400 | 225, 250, 315, 350, 400 | 3 | N | 35 | 25 | Ubushushu be-electromagnetic | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Ubushushu be-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ubushushu be-electromagnetic | ||||||||
GPM11- 630 | 630 | 400, 500, 630, 630, 700, 800 | 3 | N | 35 | 25 | Ubushushu be-electromagnetic | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Ubushushu be-electromagnetic | ||||||||
3,4 | H | 65 | 50 | Ubushushu be-electromagnetic | ||||||||
GPM11-800 | 800 | 630, 700, 800 | 3,4 | S | 50 | 35 | Ubushushu be-electromagnetic | 1000 | 4000 | |||
3,4 | H | 65 | 50 | Ubushushu be-electromagnetic |