I-GPM2.1 Isixhobo sokutshintsha i-MCC esineVoti ephantsi
Isishwankathelo sesakhiwo
Isakhelo sekhabhathi ye-GPM2.1 senziwe ngentsimbi ekumgangatho ophezulu we-aluminiyam-zinc-coated ipleyiti yentsimbi okanye ipleyiti yentsimbi eqengqelekayo ekumgangatho ophezulu ukuba igotywe ibe ziinxalenye, ezidityaniswe omnye komnye ngokuzicofa ngezikrufu zokutshixa okanye izikrufu ezinehexagonal, kwaye emva koko wongeza iingcango ezihambelanayo ngokweemfuno zotshintsho lweprogram, iipleyiti zokutywina, izahlulo, izibiyeli ezikhwelayo, iibhasi, iiyunithi ezisebenzayo kunye namanye amacandelo ahlanganiswe kwisixhobo esipheleleyo.Ubungakanani bamacandelo kwisixhobo kunye nobukhulu bekhompatimenti bamodyuli (modulus unit E=25mm).Njengesizukulwana esitsha se-low-voltage withdrawable switchgear, sinezi mpawu zilandelayo:
1. Isakhiwo sinengqiqo kwaye inqanaba lobugcisa liphezulu.Ukulinganiswa kwamandla okuthwala ngoku, amandla okuphuka kunye nokuzinza okuguquguqukayo kwe-thermal ye-GPM2.1 i-switchgear ephezulu kunezinye iintlobo ze-low-voltage switchgear, kwaye kulula ukuyigcina, ikhuselekile kwaye inokwethenjelwa.
2. Ukusebenza kakuhle kokukhusela.I-GPM2.1 sisitshixo sokutshintsha esizimeleyo ngokupheleleyo, igumbi langaphakathi lihlangabezana neemfuno ze-IEC439-1 "iFom 3b" okanye "iFom 4b" njengokuodola, kwaye ibakala lokhuseleko lokuvalelwa yi-IP3X, IP31, IP32, IP4X, IP41, IP42, IP43 , IP5X, IP54 njengokuodola.
3. I-interlock ithembekile.I-GPM2.1 ye-anti-misoperation interlock igqitywe ngokudibeneyo yi-circuit breaker operating system kunye ne-drawer position mechanical interlocking operating mechanism.Uyilo lwayo luchanekile kwaye lunengqiqo, olunokuthi luthintele ngokufanelekileyo ukungahambi kakuhle okunokwenzeka kwaye lunokusetyenziswa kunye nemowudi yokusebenza ukuze iqonde ngokuguquguqukayo ukudibanisa phakathi kweekhabhinethi.
4. Kukho izicwangciso ezininzi kwaye zigqityiwe kwaye zilula ukudibanisa.I-GPM2.1 ithatha i-8E njengeyunithi eyisiseko, kwaye iiyunithi ezisebenzayo ziyi-8E / 4, 8E / 2, 6E, 8E, 12E, 16E, 24E, 32E, 72E.Uninzi lweeyunithi ezisebenzayo ezingama-36 zinokulungiswa kwikhabhinethi enye ye-MCC, kwaye inokufezekiswa.Ukufakwa okuxubileyo kwePC kunye ne-MCC kubonelela ngeemeko ezifanelekileyo zokunciphisa inani leekhabhinethi kunye nezisombululo eziguquguqukayo.
I-GPM2.1 i-low-voltage drawer switchgear iyisixhobo sokulawula esinobuchwepheshe obuphezulu, ukusebenza okuzinzile, isakhiwo esifanelekileyo, ukusetyenziswa kakuhle, okukhuselekileyo nokuthembekileyo.Isetyenziswe ngokubanzi kubonelelo lwamandla kunye neenkqubo zokusasaza ezifana nokuvelisa amandla, ukwakhiwa, intsimbi, isamente, imigodi, kunye nepetrochemical.