Imeko ye-ambient
Ubushushu be-Ambient: -25℃~+45℃, umndilili wemihla ngemihla: ≤35℃
Ukuphakama: 1000m( Standard);ingaya kuthi ga kwi-4500m ukulungiselela iodolo ekhethekileyo;
Ukufuma okuhambelanayo: umyinge wemihla ngemihla ≤95%, umyinge wenyanga ≤90%;
Ubunzulu benyikima ≤8 degree;
Izihlandlo ezisebenzayo kufuneka zingabikho kwizinto ezinokutsha, kwiziqhushumbisi, kwizidlelezi kunye nokungcangcazela okukhulu.
Umzekelo
Products feature
1) Le mveliso iyasebenza kwi-GPVN-12kV/17Kv/24kV yethu eyenziweyo okanye i-insulating sleeve vacuum breaker okanye i-ABB's VD4 i-vacuum breaker.
2) Uqwalaselo lwethu lokuvelisa i-GPVC i-vacuum contactor - indibaniselwano ye-fuse okanye i-VC yenkampani ye-ABB i-VC vacuum contactors, enokuthi yenziwe nge-FC loop cubicle, ukuhlangabezana nenkqubo yombane wezityalo zamandla kunye nemfuno yamanye amashishini kunye nemigodi.
3) Ukusebenzisa i-aluminiyam-zinc egqwesileyo ipleyiti yentsimbi ngokuchaneka kwezixhobo zomatshini zeCNC ezihlanganiswe kwikhabhinethi, kunye nokusetyenziswa kwenkqubo yokugoba kabini, kuphucula kakhulu amandla ekhabhinethi.
4) Umphezulu womnyango nge-epoxy resin electrostatic powder spray process, ukumelana nokubola, i-oxidation, impembelelo kunye nokubambelela okunamandla.
5) Isakhiwo seKhabhinethi esivalwe ngokupheleleyo sifezekiswa sixhobe ngokupheleleyo, iiyunithi ezisebenzayo zahlulwe ngokupheleleyo.Xa umnyango uvaliwe, unokufezekisa ukusebenza kwe-circuit breaker kunye nokutshintsha komhlaba.
6) Ukuchaneka kwe-screw drive mechanism, qinisekisa itroli ngokutshintshana okulungileyo.
7) Isicwangciso sokuqala esigqibeleleyo sokuhlangabezana neemfuno ezahlukeneyo zabasebenzisi, kwaye yenza isicwangciso setroli esiphindwe kabini.
I-8) Ukutshintsha ngokukhawuleza ukutshintshwa komhlaba kunye neesekethe ezimfutshane, kunye nokufezekisa ukusebenza kombane (Motorized).
9) Indlela elula nesebenzayo "yoKhuseleko oluHlanu" olunxibelelanayo lunokuthintela ngokuthembekileyo ukusetyenziswa kakubi kunye nokuqinisekisa ukhuseleko lwabasebenzisi.
I-10) I-switchgear yeyohlobo lwe-Arc-proof, phezu kwekhompatimenti yebhasi, i-Vacuum circuit breaker compartment, kunye ne-cable terminal compartment ixhotyiswe ngezixhobo zokunciphisa uxinzelelo.
I-11) I-cable compartment inendawo eyaneleyo, inokudibaniswa lula kubuninzi beentambo, kwaye uqinisekise ukuphakama kofakelo lweplagi yekhebula.
I-12) Umlinganiselo wokukhusela ongqongqo (IP4X), ukukhusela ngokufanelekileyo umcimbi wangaphandle okanye ukuhlasela kwezinambuzane.
I-13) Inkqubo yesibini ekhethiweyo ilandela isixhobo sokubeka iliso sokhuseleko sinomsebenzi wokuzixilonga kunye nokunxibelelana kwedatha, ikhompyutha edibeneyo ehlakaniphile, ukufezekisa ulawulo olukude, i-telemetry ekude, ukujonga kude, ukulungiswa okude.
14) Hlangana ne-GB3906, i-GB / T11022, i-DL404 kunye ne-IEC60298, imigangatho ye-IEC62271-1, kunye novavanyo olubanzi lovavanyo kunye novavanyo lwe-plateau (3000 m).
15) Uphumelele iimvavanyo zokuhambelana kwe-electromagnetic kwilabhoratri yovavanyo lwezixhobo zombane ophezulu.
A. Iinkcukacha zobuchwephesha Kwi-switchgear ye-12Kv
Into | Iyunithi | Idatha | |
Umbane olinganisiweyo | kV | 6-12 | |
Ilinganiswe rhoqo | Hz | 50/60 | |
Ikalwe ngoku | A | 630~4000 | |
Inqanaba lokufakwa kwe-insulation | 1min frequency amandla (Inqanaba emhlabeni / ngaphaya kwabafowunelwa abavulekileyo) | kV | 42/48 |
Impembelelo yombane imelana nombane (Inqanaba emhlabeni / ngapha kwabafowunelwa abavulekileyo) | kV | 75/85 | |
Ibha yebhasi ephambili inikwe umlinganiselo wangoku | A | 1250,1600,2000,2500,4000 | |
I-Sub-busbar inikwe umlinganiselo wangoku | A | 630,1250,1600,2000,2500,3150 | |
Ilinganiswe ngexesha elifutshane lokumelana nangoku(4s) | kA | 16,20,25,31.5,40,50 | |
Incopho elinganisiweyo ukumelana yangoku | kA | 40,50,63,80,100,125 | |
Isidanga soKhuseleko | I-IP4X ebiyelweyo, IP2X(ivuliwe ucango lweVCB) | ||
Ubungakanani benkcazo (ububanzi/ubunzulu/ubude) | mm | 650(800,1000) /1500(1300,1670,2000) /2300 | |
Ubunzima | kg | 500~1200 |
Umzobo wesakhiwo se-cubicle 630A ~ 1250A
Umzobo wesakhiwo se-cubicle 1600A ~ 4000A
B.Itheyibhile yeeparamitha eziphambili ze-17.5kV switchgear
Hayi. | Igama | Iyunithi | Idatha | |
1 | Umbane olinganisiweyo | kV | 15/17.5 | |
2 | Inqanaba lokufakwa kwe-insulation | Imizuzu eyi-1 yombane wokuxhathisa amandla ombane (RMS) | kV | 50 |
Impembelelo yokukhanya imelana nombane (incopho) | 95 | |||
3 | Ikalwe ngoku | A | 630~4000 | |
4 | Ilinganiswe ngokuvula isiphaluka esifutshane | kA | 50 | |
5 | Ilinganiswe ngamaza ombane | Hz | 50/60 | |
6 | Ulinganiso lwendlela emfutshane yokwenza yangoku(incopho) | kA | 130 | |
7 | Incopho elinganisiweyo ukumelana yangoku | kA | 130 | |
8 | Ilinganiswe ngexesha elifutshane lokumelana nangoku | kA | 50 | |
9 | Ubomi bombane | amaxesha | 20 | |
10 | Ilinganiswe ngobude bexesha langoku lesekethe emfutshane | s | 4 | |
11 | Ubomi boomatshini beVCB | amaxesha | 10000 | |
12 | Iqondo lokukhusela le cubicle | I-IP4X ebiyelweyo, IP2X(ivuliwe ucango lweVCB) | ||
13 | Ubungakanani bolwandlalo (W*D*H) | mm | 800/1000*1500/1670*2300 | |
14 | Ubunzima | kg | 500~1200 |
C. Iinkcukacha zobuchwephesha ze-24kV switchgear
Into | Iyunithi | Idatha | |
Umbane olinganisiweyo | kV | 24 | |
Ilinganiswe rhoqo | Hz | 50/60 | |
Ikalwe ngoku | A | 630,1250, 1600, 2500, 3150, 4000 | |
Inqanaba lokufakwa kwe-insulation | 1min frequency amandla (inqanaba emhlabeni / ngapha kwabafowunelwa abavulekileyo) | kV |
65 |
Impembelelo yombane imelana nombane (inqanaba emhlabeni / ngapha kwabafowunelwa abavulekileyo) | kV |
125 | |
Ilinganiswe ngexesha elifutshane lokumelana nangoku(4s) | kA | 20, 25, 31.5 | |
Incopho elinganisiweyo ukumelana yangoku | kA | 50, 63, 80 | |
Isidanga soKhuseleko | Indawo ebiyelweyo: IP4X, ucango luvuliwe: IP2X | ||
Umlinganiselo wenkcazo (ububanzi x ubunzulu x ubude) | mm | 1000(800)x1820(1500)x2430(2300) | |
Ubunzima | kg | 1200-1500 |
1. Umthamo wesekethe emfutshane yeCT uya kuqwalaselwa ngokwahlukileyo;
2. Umzobo womgca ophumayo ongasemva kufuneka ube ne-cubicle eyongezelelweyo.