I-GPN1-40.5kV Ekhutshwayo ye-AC yesinyithi-egqunywe iSwitchgear evalelweyo
Isishwankathelo
I-GPN1-40.5kV esuswayo ye-AC ye-metal-clad switchgear (ifutshane kwi-switchgear njengoko ingezantsi) isebenza kwi-40.5kV, isigaba se-3, i-AC kunye ne-50 / 60Hz inethiwekhi yamandla ombane yokufumana kunye nokusabalalisa amandla ombane kunye nokulawula, ukubeka iliso kunye nokukhusela.Isebenza kwisixokelelwano samandla ngokubanzi kunye nezihlandlo ezisebenza rhoqo.Imveliso ihambelana ne-GB 3906 "3 ~ 35kV AC Metal Enclosed Switchgear", i-GB / T 11022 "Amagatya obugcisa aqhelekileyo oMgangatho we-High Voltage Switchgear kunye ne-controlgear Standard", i-DL / T 404-1997 "Umyalelo weTechnical term ye-Indoor AC High Voltage Switchgear ” kunye ne-IEC-298 “1~52kV AC Metal Enclosed Switchgear and Controlgear standard”.
Imeko ye-Ambient
Ubushushu be-Ambient: -25℃~+45℃, umndilili wemihla ngemihla: ≤35℃
Ukuphakama: 1000m(Standard);ingaya kuthi ga kwi-4500m ukulungiselela iodolo ekhethekileyo;
Ukufuma okuhambelanayo: umyinge wemihla ngemihla ≤ 95%, umyinge wenyanga ≤ 90%;
Ubunzulu benyikima≤8 degree;
Izihlandlo ezisebenzayo kufuneka zingabikho kwizinto ezitshisayo, ezinokutsha kunye nomphunga.
Umzekelo
Uphawu lweMveliso
I-switchgear yiyunithi yendibano kwaye i-breaker circuit ithatha imodeli yomgangatho wenqwelo yesandla.Ingumnikazi wokutshintsha ngokulula kunye nokutshintshiselana kakuhle emva kokuxhobisa nge-vacuum vacuum breaker yesekethe ephezulu.Indlela yokuqhubela phambili ye-screw nut ifakwe kwifreyimu yenqwelo yesandla yokuthintela ekusebenzeni kwempazamo kunye nokonakalisa indlela yokuqhubela phambili, inqwelo yesandla inokususwa ngokulula;Onke amanyathelo okusebenza anokwenziwa kwimeko yokuvala;Kunyanzelekile ukutshixa phakathi kokutshintsha okuphambili, inqwelo yesandla kunye nomnyango wepaneli ukuhlangabezana nokhuseleko oluhlanu;indawo ebanzi yokudibanisa iintambo ezininzi kwi-cubicle yentambo.I-Earthing switch isetyenziswa kwi-earthing kunye ne-loop yesiphaluka esifutshane, i-degree degree yokukhusela i-IP3X, i-IP2X phantsi kwemeko yokuvula.
Inkcazo yobuGcisa
Hayi. | Into | Iyunithi | Idatha | |
1 | Umbane olinganisiweyo | kV | 36/38/40.5 | |
2 | Ikalwe ngoku | A | 1250, 1600, 2000, 2500 | |
3 | Ilinganiswe rhoqo | Hz | 50/60 | |
4 | Ilinganiswe kwisekethe emfutshane yokwaphulwa kwangoku | kA | 25, 31,5 | |
5 | I-4s inikwe ixesha elifutshane ukumelana nangoku | kA | 25, 31,5 | |
6 | Ilinganiswe kwisekethe emfutshane yokwenza yangoku (incopho) | kA | 63, 80 | |
7 | NONE | kA | 63, 80 | |
8 | Inqanaba le-insulation | Impembelelo yombane elinganisiweyo imelana nombane | kV | 185 (kubafowunelwa abavulelekileyo: 215) |
Isekethe engundoqo i-1min frequency yamandla yokumelana nombane | kV | 95 (kubo bonke abafowunelwa abavulekileyo: 110) | ||
Isekethe encedisayo i-1min yamandla ombane wokuxhathisa amandla ombane | kV | 2 | ||
9 | Ubungakanani bolwandlalo(W)*(D)*(H) | mm | 1400/2800/2600 (GPN1 uhlobo) 1200/2600/2400 (Yeye-VD4/HD4 uhlobo) | |
10 | Isidanga soKhuseleko | IP3X (ikhompatimenti IP2X) | ||
11 | Ubunzima | ikg | 1000-1850 (uhlobo lweGPN1) 850-1850 (Kuhlobo lweVD4/HD4) |
Uphawu lolwakhiwo
I-switchgear iyahlula kwi-enclosure kunye ne-handcart, i-enclosure yenziwe nge-aluminium-zinc plated sheet sheet emva kokucutshungulwa ngumatshini we-CNC kunye nokugoba okuninzi, emva koko ihlanganiswe kunye neebholiti.Ke inamandla omatshini anamandla kwaye inokuqinisekisa ukucoceka kunye nenkangeleko entle.Ibandakanya indawo yokuhanjiswa, indawo yenqwelo yesandla, indawo yekhebula, idigri yokhuseleko yi-IP2X xa i-CB handcart ikwindawo yokuvula kunye novavanyo.
I-switchgear luhlobo lwentsimbi olukhuphayo, isekethe ephambili ithatha ukucutshungulwa kwe-composite insulation, ukusasazeka ngokukhawuleza kwezinye iindawo.I-CT kunye ne-earth switching zifakwe kwi-cable compartment kunye ne-busbar compartment.Iqondo lokhuselo lwe-enclosure yi-IP3X, ukhuseleko kunye nendawo enkulu yeentambo ezininzi.Uyilo lolwakhiwo lweVCB entsha egqunywe ngokupheleleyo okanye iSF6 CB kunye nendlela yokusebenza yasentlakohlaza yimodeli yekhonsoli edityanisiweyo kunye nokugqwesa okutshintshiselana kakuhle kunye nokutshintsha ngokulula.