GPR-24 series Ring Main Unit iyanwebeka, SF6isixhobo sokutshintsha esigqunyiweyo, esinombane olinganisiweyo we-12&24 kV.Zonke iindawo zayo eziphilileyo ze-HV ziqulathwe kwitanki yerhasi engangeni moya, eyenziwe ngentsimbi engatyiwayo eyi-3mm.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Isishwankathelo

GPR-24 series Ring Main Unit sisixhobo esandisiweyo, SF6 insulated switchgear, kunye amandla ombane ezilinganiselwe 12 & 24 kV.Zonke iindawo zayo eziphilileyo ze-HV ziqulathwe kwitanki yerhasi engangeni moya, eyenziwe ngentsimbi engatyiwayo eyi-3mm.Yonke indibano yokutshintsha i-SF6 igqunyiwe, kwaye ikhululekile kuyo nayiphi na impembelelo yangaphandle, iqinisekisa ukuthembeka okukhulu kwenkonzo kunye nokugcinwa simahla.Ngohlobo lwe-plug-in ye-busbar extension, i-GPR-24 series Ring Unit Unit ingaba yindibaniselwano yamahhala kunye ne-modularization epheleleyo.Ukwandiswa kwebhasi yebhasi kuphumelele uvavanyo lohlobo lwamandla kunye nokuzinza kwe-thermal, kwaye ifakwe ngokupheleleyo kwaye ikhuselekile, ibonisa ukuthembeka okuphezulu kunye nokhuseleko.GPR-24 series Ring Main unit ilungele yonke inethiwekhi ye-MV ukuya kuthi ga kwi-24 kV, zonke izikhululo zamandla ezidityanisiweyo, izitishi zokuhambisa amandla kuwo onke amashishini abalulekileyo, afana neshishini lepetroli-lekhemikhali, i-metallurgical kunye nemigodi yemigodi, kunye nazo zonke izitishi ze-transformer kunye namandla omoya. inkqubo.

Iimbonakalo

1. Inkqubo yenkqubo ephuculweyo yetanki yegesi
Inkqubo ye-laser elawulwa yidijithali yokusika kunye ne-punching system kunye ne-three-dimension kunye ne-five-axis laser welding system engeniswe eJamani kunye nokuqinisekisa ukuqina kwegesi kunye nokufana kwazo zonke iitanki zegesi.
Inkqubo yokufumanisa ukuvuza kwe-helium ezenzekelayo ngokupheleleyo kunye nedityanisiweyo, eyenziwe ngu-SEILER Vakuumtechnik GmbH, ngokuchongwa kokuvuza kwe-Helium nge-mass spectrograph, izisa izinga lokuvuza kwerhasi ngonyaka ukuya ngaphantsi kwe-0.02%, iqinisekisa ubude bobomi betanki yegesi engaphezu kweminyaka engama-30.
Ubuchule benkqubo ekwinqanaba eliphezulu .
Onke amalungu e-epoxy resin insulated, kubandakanywa nezibonda ezigqunyiweyo, zenziwa ngokuzenzekela ngokuzeleyo kunye nokulawulwa ngokwedijithali kwe-epoxy resin vacuum mixing/pressure gelatinizing system esuka eHedrich (eJamani).
Umdibaniso webhasi, umdibaniso wekhebula, iplagi yokuphela kunye nezinye iirubha ze-silicone ezifakwe kwi-rubber zifakwe kwi-automatic kunye ne-digitally controlled silicone rubber mixing/pressure gelatinizing system from VOGEL (Switzerland).
2. Izisombululo ezigqwesileyo zeemveliso
Ngesakhiwo esincinci kunye nesincinci, iiyunithi ezisisiseko zokusebenza K, T, V, B kunye ne-C zinemilinganiselo efanayo: 350 * 800 * 1380 mm (ububanzi * ubunzulu * ubude) .
Gqibezela izisombululo:
Inguqulelo enye: iyunithi yokutshintsha ikhefu lomthwalo, iyunithi yokutshintsha i-fuse, iyunithi yokuqhawula i-vacuum, iyunithi yecandelwana lebhasi, iyunithi yentambo, iyunithi yokulinganisa, njl.
Uguqulelo lwebhloko lunokwenziwa ezimbini, ezintathu, ezine, ezintlanu okanye ezintandathu iiyunithi ezisebenzayo.
Iiyunithi ezingatshatanga kunye noguqulelo lwebhloko lunokudityaniswa ngeziqhagamshelo zebhasi eziguquguqukayo.
3. Ukuziqhelanisa okuqinileyo nokusingqongileyo
Inkqubo ephambili yokuqhubela phambili ivalwe ngokupheleleyo kwitanki yegesi ye-SF6 kwaye ayiyi kuphenjelelwa yimeko yangaphandle, ezimeleyo kwimpembelelo yombethe, uthuli, inkungu yetyuwa, njl. Ngoko ke, uchungechunge lwe-GPR-24 lunokusetyenziswa kwiimeko ezahlukeneyo zenkonzo. .

12kV Idatha yoBugcisa

Inkcazo

Iyunithi

Iyunithi ye-LBS

Iyunithi yokutshintsha-i-fuse

iyunithi yeVCB

Iyunithi yecandelwana lebhasi

Umbane olinganisiweyo

kV

12

12

12

12

Amandla ombane okumelana nombane (1min)

Isigaba ukuya kwisigaba/emhlabeni

kV

42

42

42

42

Ukuwela umgama owahlukileyo

kV

48

48

48

48

Impulse imelana nombane

Isigaba ukuya kwisigaba/emhlabeni

kV

75, (95)*

75, (95)*

75, (95)*

75, (95)*

Ukuwela umgama owahlukileyo

kV

85, (110)*

85, (110)*

85, (110)*

85, (110)*

Ilinganiswe rhoqo

Hz

50,60

50,60

50,60

50,60

Ikalwe ngoku

A

630

630

630

Ilinganiswe kwisekethe emfutshane yokwaphulwa kwangoku

kA

20, (25)*

Ilinganiswe ngexesha elifutshane lokumelana nangoku

kA/s

20/3,

(20/4, 25/1)*

20/3,

(20/4, 25/3)*

20/3,

(20/4, 25/1)*

Incopho elinganisiweyo ukumelana yangoku

kA

50, (63)*

50, (63)*

50, (63)*

Ilinganiswe kwisekethe emfutshane yokwenza yangoku

kA

50, (63)*

50, (63)*

50, (63)*

Udluliselo olulinganisiweyo lwangoku

A

1800

Ireyithwe ngumthwalo osebenzayo wokwaphulwa kwangoku

A

630

630

Ilinganiswe ngokuqhawula iluphu evaliweyo

A

630

630

I-5% ilinganiswe ngumthwalo osebenzayo wokwaphulwa kwangoku

A

31.5

31.5

Ulandelelwano lokusebenza olukalwe

O-0.3s-CO-180s-CO

Ubomi boomatshini

Ops.

5000

5000

10000

5000

Ubomi bombane

E3

E2

E3

Ukutyeba kwentsimbi engenasici

mm

3.0

Ilinganiswe SF6uxinzelelo

kPa

30 (ku-20℃, 101.3kPa)

Izinga lokuvuza lonyaka

 

<0.02%

Uvavanyo lonyango lwamanzi

 

12kV iiyure ezingama-24 (ngama-30 kPa phantsi kwamanzi)

Uvavanyo lwangaphakathi lwe-arc

 

20kA1s

Isidanga soKhuseleko

Itanki yegesi

 

IP67

Isibambi se-fuse

 

IP67

GPR ebiyelweyo

IP 4X

24kV Idatha yoBugcisa

Inkcazo

Iyunithi

Iyunithi ye-LBS

Iyunithi yokutshintsha-i-fuse

iyunithi yeVCB

Iyunithi yecandelwana lebhasi

Umbane olinganisiweyo

kV

24

24

24

24

Amandla ombane okumelana nombane (1min)

Isigaba ukuya kwisigaba/emhlabeni

kV

50, (65)*

50, (65)*

50, (65)*

50, (65)*

Ukuwela umgama owahlukileyo

kV

64, (79)*

64, (79)*

64, (79)*

64, (79)*

Impulse imelana nombane

Isigaba ukuya kwisigaba/emhlabeni

kV

95, (125)*

95, (125)*

95, (125)*

95, (125)*

Ukuwela umgama owahlukileyo

kV

110, (145)*

110, (145)*

110, (145)*

110, (145)*

Ilinganiswe rhoqo

Hz

50, 60

50, 60

50, 60

50, 60

Ikalwe ngoku

A

630

630

630

Ilinganiswe kwisekethe emfutshane yokwaphulwa kwangoku

kA

20

Ilinganiswe ngexesha elifutshane lokumelana nangoku

kA/s

20/3, (20/4)*

20/3, (20/4)*

20/3, (20/4)*

Incopho elinganisiweyo ukumelana yangoku

kA

50

50

50

Ilinganiswe kwisekethe emfutshane yokwenza yangoku

kA

50

50

50

Udluliselo olulinganisiweyo lwangoku

A

1400

Ireyithwe ngumthwalo osebenzayo wokwaphulwa kwangoku

A

630

630

Ilinganiswe ngokuqhawula iluphu evaliweyo

A

630

630

I-5% ilinganiswe ngumthwalo osebenzayo wokwaphulwa kwangoku

A

31.5

31.5

Ulandelelwano lokusebenza olukalwe

O-0.3s-CO-180s-CO

Ubomi boomatshini

Ops.

5000

5000

10000

5000

Ubomi bombane

E3

E2

E3

Ukutyeba kwentsimbi engenasici

mm

3.0

Ilinganiswe ngoxinzelelo lwe-SF6

kPa

30 (ku-20℃, 101.3kPa)

Izinga lokuvuza lonyaka

<0.02%

Uvavanyo lonyango lwamanzi

24kV iiyure ezingama-24 (ngama-30 kPa phantsi kwamanzi)

Uvavanyo lwangaphakathi lwe-arc

20kA1s

Isidanga soKhuseleko

Itanki yegesi

IP67

Isibambi se-fuse

IP67

GPR ebiyelweyo

IP 4X

Amanqaku:
① Ireyithingi yangoku yeyunithi yokutshintsha-fuse ixhomekeke kukalisho lwefuse: ≤100A
② Ireyithingi yokwaphulwa kwesekethe emfutshane/ukwenziwa kwangoku kweyunithi yokutshintsha-ifuse kuxhomekeke kumlinganiselo wefuse
* Amaxabiso kwizibiyeli ayimfuneko ekhethekileyo, nceda uqhagamshelane nomenzi okanye umthengisi ngolwazi olungakumbi

GPR24 Series Overview

1. Uhlobo lwetanki enye

Hayi.

Uhlobo

Igama

Amabanga aphantsi

Umzobo

Ubungakanani W*D*H(mm)/Ubunzima(kg)

Inkcazo

12kV

24kV

1

GPR24-K

Iphaneli yokutshintsha ikhefu lokulayisha

 i1

350 x 800 x 1380

/160

350 x 800 x 1380

/160

(370 x 850 x 1380

/190)*

Ukutshintsha uqhagamshelo phakathi kwentambo yangaphakathi/ngaphandle kunye nebar yebhasi yomhlaba, kunye nomthamo wokwenza isekethe emfutshane.

2

GPR24-T

Iphaneli yokutshintsha-fuse

 i2

350 x 800 x 1380

/190

350 x 800 x 1380

/190

(480 x 850 x 1380

/230)*

Kulawulo kunye nokukhusela i-transformer ukuya kwi-1250kVA

3

GPR24-V1

Iphaneli ye-vacuum ye-circuit breaker

 i3

350 x 800 x 1380

/200

350 x 800 x 1380

/200

(480 x 850 x 1380

/240)*

Kwisekethe engenayo / ephumayo, inokuxhotyiswa ngeyunithi yokukhusela i-microcomputer

4

GPR24-V2

Iphaneli ye-vacuum ye-circuit breaker

 i4

350 x 800 x 1380

/200

350 x 800 x 1380

/200

(480 x 850 x 1380

/240)*

Kwisekethe engenayo / ephumayo, inokuxhotyiswa ngeyunithi yokukhusela i-microcomputer

5

GPR24-B

Iphaneli yecandelwana leBusbar

 i5

350 x 800 x 1380

(Kwicala lasekunene lohlobo lwebhloko, ububanzi: 400mm)

/135

350 x 800 x 1380

/135

(480 x 850 x 1380

/150)*

Ngoqhagamshelo lwebhasi.

6

GPR24-V

Ukudibanisa ibhasi ye-VCB

 i6

350 x 800 x 1380

/180

350 x 800 x 1380

/180

(480 x 850 x 1380

/220)*

Kuqhagamshelo lwebhasi, esetyenziswa kuhlobo lwebhloko kuphela

7

GPR24-C

Iphaneli yokunyuka

 i7

350 x 800 x 1380

/100

350 x 800 x 1380

/100

(370 x 850 x 1380

/110)*

Kunxibelelwano lwentambo yangaphakathi/ngaphandle

8

GPR24-M

Iphaneli yokulinganisa

 i8

600 x 800 x 1380

/210

800 x 1000 x 1380

/210

(800 x 1000 x 1380

/220)*

Ukusetyenziswa kombane wokulinganisa umbane/umbane

9

GPR24-PT

Iphaneli yePT

 i9

600 x 800 x 1380/180

800 x 1000 x 1380/180

(800 x 1000 x 1380/210)*

Ukujonga amandla ombane webhasi, ukubonelela ngophawu lwamandla ombane olulahlekileyo

10

GPR24-P

Iphaneli yonikezelo lwamandla

 i10

600 x 800 x 1380/170

600 x 800 x 1380/170

(600 x 850 x 1380/180)*

Ukubonelela nge-DC 24V/48V, unikezelo lwe-AC220V

Phawula:
1. Amaxabiso kwizibiyeli eziphawulwe nge”*” ziimveliso ezikwi-24kV, i-frequency yamandla ombane imelana nombane oyi-65/79kV;
2. Ukuba kukho amacandelo amaninzi esibini kwi-configuration, i-compartment eyongezelelweyo kubo inokufakwa phezu kwepaneli, ukuphakama kwayo yi-400mm.

2. GPR24 Block type-1 for 12kV &24kV(power frequency withstand voltage: 50/64kV)

Hayi.

Uhlobo

Indibaniselwano yeyunithi

Umzobo wokuqala

Imilinganiselo WxDxH(mm)

Ubunzima (kg)

1

GPR24-KKVV

Iiyunithi ezi-2 zokuqhawula umthwalo kunye neyunithi ye-2 ye-vacuum circuit breaker

 img1

1050 x 800 x 1380

50

2

GPR24-KKTT

Iiyunithi ezi-2 zokutshintsha i-breaker load kunye ne-2 switch-fuse unit

 img2

1400 x 800 x 1380

700

3

GPR24-5K

Iiyunithi ezi-5 zokutshintsha i-breaker load

 img3

1750 x 800 x 1380

800

4

GPR24-KKKTT

Iiyunithi ezi-3 zokuqhawula umthwalo kunye neeyunithi ezi-2 zokutshintsha-fuse

 img5

1750 x 800 x 1380

860

5

GPR24-KKTTT

Iiyunithi ezi-2 zokutshintsha ikhefu lomthwalo kunye neeyunithi ezi-3 zokutshintsha-fuse

 img4

1750x800x1380

890

Amanqaku:
Ukuba kukho amacandelo amaninzi esibini kuqwalaselo, i-compartment eyongezelelweyo kubo inokufakwa phezu kwe-GPR, ukuphakama kwayo yi-400mm.


  • Ngaphambili:
  • Okulandelayo:

  • Iimveliso ezinxulumeneyo

    >