Isixhobo esiDityanisiweyo soMlayisho woMlayisho weVacuum
Umzekelo kunye nentsingiselo
Imeko ye-Ambient
Ubushushu bendalo: Max.ixesha.+40℃;Min.ixesha.-15℃
Ukufuma kokusingqongileyo: Ukufuma okuhambelanayo ngosuku ≤ 95%;Ukufuma okuhambelanayo ngenyanga ≤ 90
Umphakamo wendawo apho inkonzo yoTshintsho ngaphakathi inokufikelela kwi-1000m
Ngemeko yenkonzo ekhethekileyo, nceda uqhagamshelane nomenzi
Umgangatho weReferensi
I-GB3804-2004 i-High-Voltage alternating-current switching for voltage rated over 3.6kV and up to and include 40.5kV
GB16926-2009 High-Voltage alternating-current switch-fuse indibaniselwano
I-GB/T11022-1999 Iinkcukacha eziqhelekileyo zesixhobo sokutshintsha i-voltage ephezulu kunye nemigangatho yokulawula
IiParameters eziPhambili zobuGcisa zoTshintsho
Igama | Iyunithi | Tshintsha GPL-24/T630-20 | Umdibaniso wokutshintsha-fuse GPLR-24/T125-40 | |
Umbane olinganisiweyo | kV | 24 | 24 | |
Ilinganiswe rhoqo | Hz | 50 | 50 | |
Ikalwe ngoku | A | 630 | 125 (ngokwefuse nganye) | |
Ikaliwe I-Insulation inqanaba | I-1min yamaxesha ombane wokuxhathisa amandla ombane | kV | Abafowunelwa beterminal kunye nabaqhekezi bavula i-65; Isigaba ukuya kwisigaba, isigaba ukuya emhlabeni 65 | |
Impembelelo yokukhanya imelana nombane | kV | Isigaba ukuya kwisigaba, isigaba ukuya emhlabeni 125; Uqhagamshelwano lweterminal kunye ne-isolators luvula i-125 | ||
Ilinganiswe kwisekethe emfutshane yokwaphulwa kwangoku | kA | - | 40 | |
Umthwalo osebenzayo wokwaphula okwangoku | A | 630 | - | |
Ilinganiswe ngokuvala iluphu yokwaphuka kwangoku | A | 630 | - | |
Umthwalo osebenzayo usezantsi ngokwaphuka kwangoku | A | 31.5 | - | |
Ireyithwe ukutshaja kwentambo eyophukayo | A | 16 | 16 | |
Ilinganiswe kwisekethe emfutshane yokwenza yangoku (incopho) | kA | 50 | 100 | |
Ilinganiswe ngexesha elifutshane lokumelana nangoku | kA | 20 | - | |
Ilinganiswe ngexesha elifutshane ukumelana nobude bangoku | S | 4 | - | |
Incopho elinganisiweyo ukumelana yangoku | kA | 50 | - | |
Ilinganiswe ngokuthatha kwangoku | A | - | 3150 | |
Ukuchasa isekethe | μΩ | ≤150 | ≤250+ Fuse | |
Amandla emoto | W | 90 | ||
Ukuhamba kunye noqhagamshelwano olusisigxina oluvumelekileyo lwe-abrasion accumulative thickness | mm | 3 | ||
Usulelo phakathi kwabafowunelwa abavulekileyo | mm | 12±1 | ||
Ixesha lokuvala uqhagamshelwano | ms | ≤2 | ||
Isigaba esi-3 se-asynchronous | ms | ≤2 | ||
Isantya sokuvala esiphakathi | Nksk | 0.8±0.2 | ||
Isantya sokuvula esiphakathi | Nksk | 1.3±0.2 | ||
Ukunyamezela komatshini | Amaxesha | 10000 |
IiParameters ezingundoqo zobuGcisa beMoto
Igama | Iyunithi | Iiparamitha |
Ixabiso lombane wokusebenza | V | AC/DC 110/220 |
Igalelo lamandla elilinganisiweyo | W | 80 |
Uluhlu lombane oluqhelekileyo lwemoto yokutshaja |
| I-85% ~ 110% Ilinganiswe amandla ombane wokusebenza |
Ixesha lokutshaja | s | ≤15 |
Ubuchwephesha obuphambili bekhoyili
Igama | Iyunithi | Iiparamitha | |
Ixabiso lombane wokusebenza | V | AC, DC110 | AC, DC220 |
Umsebenzi okalwe ngoku | A | ≤3 | ≤2 |
Uluhlu oluqhelekileyo lombane lwekhoyili esondeleyo |
| I-85% ~ 110% Ilinganiswe amandla ombane wokusebenza | |
Uluhlu lombane oluqhelekileyo lwekhoyili yohambo |
| I-65% ~ 120% Ilinganiswe amandla ombane wokusebenza |
Ulwakhiwo kunye noMsebenzi
I-GPL (R) uhlobo lokutshintsha lubandakanya umatshini wokusebenza kunye namagumbi okucima i-arc kwilungiselelo langaphambili, isiphaluka sayo esiphambili somqhubi wesakhiwo somgangatho womgangatho.Igumbi lokucima i-arc-vacuum ligxininiswe kwikholamu ethe nkqo ye-cannular insulation eyenziwe nge-epoxy resin yitekhnoloji ye-APG, ngenxa yoko nge-anti-creepage elungileyo kakhulu, uyilo olunjalo lolwakhiwo olukhulu olunciphisa ukuqokelelwa kothuli kumphezulu wegumbi lokucima i-arc, Ayinakuthintela kuphela igumbi lokucima ivacuum kwimpembelelo yangaphandle, kodwa inokuqinisekisa ukuba ibonelela ngemeko ephezulu yokuchasa ngokuchasene nefuthe lombane nakwimozulu eshushu-emanzi okanye kwindawo engcolisekileyo.
Indlela yokusebenza yasentwasahlobo elungiselelwe ukulahlwa kwendiza inokuhlawulwa nge-manual okanye i-motor, indlela yokusebenza ebekwe kwibhokisi yentsimbi emiswe phambi kwegumbi lokucima i-arc.Ibhokisi yohlulwe ibe yindawo yokuhlanganisa ezintlanu ngeebhodi ezine, kwesi sithuba kukho icandelo lokutshaja, icandelo lokuntywila, icandelo elikhuphayo kunye nesithinteli somatshini ngokwahlukeneyo.Ubume be-GPL (R) uhlobo lokutshintsha apho umatshini wokusebenza kunye namagumbi okucima i-arc alungelelaniswe kwisakhiwo esihlangeneyo sangaphambili sinokuhambelana kakuhle nokusebenza kwendlela yokusebenza kunye nokusebenza okufunekayo ekuqhekezeni kunye nokwenza igumbi lokucima i-arc.Kwakhona, inokunciphisa imiqathango yaphakathi engafunekiyo kwaye inciphise ingxolo kunye namandla asetyenzisiweyo ukukhokelela ekusebenzeni kwe-GPL(R) ethembekileyo kakhulu.