Izalathisi kunye nemitha yaMandla
Uhlobo lweNkcazelo
Uhlobo | Into | Indlela yokubonisa | Amandla | Ukutshixa enye | Ukutshixa uqhagamshelwano oluphindwe kabini | Faka | Ubuqu | Ubungakanani | Ukusika ubungakanani | Umzobo | |
khangela | uqhagamshelwano | khangela | |||||||||
Uhlobo lwe-builtin | GPXN-Q | Iqhosha-cofa | - | 96×48×88 | 91×44 | 3 | |||||
GPXN-T | Iqhosha-cofa | 96×48×55 | 91×44 | 3 | |||||||
Swg. | GPXN1-Q | Ukuqaqamba | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN1-T | Ukuqaqamba | - | 96×48×55 | 91×44 | 1 | ||||||
GPXN4-Q | Iqhosha-cofa | - | - | 144×48×104 | 138×44 | 4 | |||||
GPXN4-T | Iqhosha-cofa | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN5-Q | Iqhosha-cofa | - | - | 96×48×88 | 91×44 | 2 | |||||
GPXN5-T | Iqhosha-cofa | - | 96×48×55 | 91×44 | 2 | ||||||
I-Insulator enye eneZalathi ezi-2 | GPXN4-Q/M | Iqhosha-cofa | - | - | 144×48×104 | 138×44 | 4 | ||||
GPXN4-T/M | Iqhosha-cofa | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN4-T/Z | Iqhosha-cofa | 144×48×104 | 138×44 | 4 | |||||||
Uhlobo olukhethekileyo | GPXN1-Q/CS | Ukuqaqamba | - | - | - | 96×48×88 | 91×44 | ||||
GPXNP1-Q/W | Ukuqaqamba | - | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN-Q/LCS | Ukuqaqamba | - | - | 96×48×88 | 91×44 | 3 |
Isalathisi sombane esisetyenziswa kwiYunithi ePhambili yeRingi
Isalathisi sombane sisetyenziswa kunye ne-insulator ukubonisa imeko yombane yombane wokujikeleza.
Umtshini wombane oqhubekayo we-GPXN9-C usetyenziswa kunye nesalathisi sokubonisa imeko yombane.Umgama womngxuma wetheminali yokukhangela amandla yi-14mm okanye 19mm.
Isigaba sokuthelekisa i-GPXN-C sisetyenziswa kunye nesalathisi sokubonisa imo yombane we-high-voltage circuitry kunye nokujonga ukulandelelana kwesigaba sezixhobo zombane.
Ukukhangela amandla: umlinganisi wesigaba faka kwi-earthing okanye kwezinye iitheminali zesixhobo sombane ophezulu.
Isigaba sokuhlola: i-fase comparator faka kwi-terminal yesigaba esifanayo sokukhangela izixhobo ezimbini ze-voltage ephezulu, ukuba ukukhanya kwe-LED kukhanyayo, kubonisa ukuba isigaba sokuvavanya sinombane.
Isikhundla Isalathisi
Isalathisi sendawo sinokulinganisa indawo yokusebenza kunye nemeko yezixhobo zokutshintsha njengokutshintsha kunye ne-breaker circuit kwisistim yombane.Isetyenziswa kakhulu kuzo zonke iintlobo zebhodi yokulingisa yegumbi lolawulo eliphakathi kunye nephaneli yesixhobo sokutshintsha kwiplanti yamandla, isikhululo samandla kunye nesikhululo soguqulo.Olu luhlu lwezalathisi zesikhundla lunokuthembeka okuphezulu, uluhlu olubanzi lwamandla ombane osebenzayo kunye nobomi obude.I-DC kunye ne-AC ziyafumaneka ukuze zisetyenziswe.
Iiparamitha zobuGcisa
Umbane olinganisiweyo | DC/AC 98V~242V |
Ukuqina okukhanyayo | >40 cd/㎡ |
Amandla ombane axhathise amandla ombane | 2kV/1min |
Ukumelana ne-insulation | ≥100MΩ |
Ukutshatyalaliswa kwamandla | ≤1W |
Ubushushu bokusebenza | -15℃ ukuya +50℃ |
Umsebenzi wobomi | iminyaka engaphezu kwe-10 |
Bonisa umsebenzi | Imeko yokusebenza iboniswa ngombala obomvu/oluhlaza kunye nemizobo (Njengokhetho lwabathengi) |
Umda wolwandlalo: | 37.5×37.5×62(mm) |
Ubungakanani bokusika: | Φ25(mm) |
Umzekelo | Inkcazo |
GPWZ25-K/2 | Isikhundla Isalathisi-Sekethe-Breaker |
GPWZ25-E/1 | Isikhundla Isalathisi-Earthing Switch |
GPWZ25-B/2 | Isikhundla Isalathisi-Ukuphatha ilori |
GPWZ25-B/1 | Isikhundla Isalathisi-Uqhawulo |
GPWZ25-K/1 | Isalathisi sendawo-Tshintsho lwendawo eziNtathu |
Isikhundla esibonisa isikrini i-GPAS-72
Isikhundla se-serial ye-GPAS-72 ebonisa isikrini sithatha i-LED njengomthombo wokukhanya, kunye nokusetyenziswa kwamandla aphantsi, ukuthembeka okuphezulu, ubomi benkonzo ende, njl njl.Ngemisebenzi emininzi yesalathiso sesigaba se-voltage, i-interlock, iqondo lobushushu kunye nolawulo lokufuma, isalathisi sendawo yenqwelo yesandla, isalathisi semo yomephuli wesekethe, isalathisi sokutshintsha komhlaba, isalathiso samandla agciniweyo.Lukhetho olulungileyo lokutshintsha indawo yesalathiso semeko yotshintsho lwemveli.
Iiparamitha zobuGcisa
Umbane olinganisiweyo | AC/DC 110V/220V |
Ukuxhathisa amandla | 2kV/min |
Indawo yokusebenza | -25℃ ukuya ku-55 ℃, ≤90%RH |
Isalathisi sokukhanya kokukhanya kokukhanya | >40cd/m2 |
Ubomi bokusebenza | I-10 iminyaka |
Inqanaba lokhuseleko | IP42 |
Ubungakanani | 199x146x63mm |
Ukusika ubungakanani | 177x121mm |
I-Technical ParametersGpj-3100 Series Isetyhula emfutshane kunye neSalathi seFault yoMhlaba
I-GPJ-3100 uchungechunge lwesiphaluka esifutshane kunye nesalathisi somhlaba senzelwe ukuvavanya kunye nokubonisa isiphaluka esifutshane kunye nephutha lomhlaba ngexesha langempela.Isetyenziselwa ukubeka iliso kwiisekethe kwi-RMU, umgca ongaphezulu, umgca wokusabalalisa intambo yamandla, i-box-type transformer kunye nezinye iindawo ezifanayo.Ngokomqondiso we-alam obonakaliswe sisalathisi, abasebenzi banokufumanisa kwaye banqumle indawo yempazamo ngokukhawuleza xa isekethe emfutshane okanye impazamo yomhlaba isenzeka kwisekethe, ngoko ke inkqubo inokuphinda ibonelele amandla kwindawo engenasiphako ngokukhawuleza ukonga ixesha kunye nokuphucula ukusebenza kakuhle.
Idatha yoBugcisa
1. Isekethe emfutshane eyothusayo ngoku: 100A ukuya kwi-1000A ukulibaziseka kwexesha le-40ms
2. Umhlaba owothusayo ngoku: 20A, 30A, 40A, 50A, 60A±10% ukulibaziseka kwexesha 40ms
3. Uluhlu lobushushu : -25 ukuya +70 ℃
4. Uluhlu lokufuma: ≦95%
5. Ubude belothe yomhlaba: 4m
6. Ukuqhuba ubude befiber optical 3.5m
7. Ukunikezelwa kwamandla: ibhetri ye-lithium 3.6V / 2.45Ah
8. Ukusetha ngokutsha ixesha : 7s, 2hrs, 4hrs, 8hrs
9. Ukuhanjiswa kwemveliso : 120 V AC 1A, 30V DC 2A
10.Ubungakanani bomlawuli oyintloko : 95x50x80mm
11.Ubungakanani bomngxuma wokusika : 91x44 mm
12.Iklasi yoKhuselo : UMlawuli oyiNtloko :IP40, iSensor:IP65